<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15302</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Separator obstructed by picker
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Select the RESUME button on the workstation dialog box. If this fails to correct
the problem, open the plate cover and inspect the plate separator arms and the
picker head. The picker should be in the OUT position (i.e. AWAY from the plate
stack) and the picker out magnetic reed switches should be tripped. The plate
separator arms should be free to move. If everything looks normal, then Creo
Service should be called.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error is reported when the plate seperator arms are attempting to move and
the firmware detects that the picker is NOT in the OUT position (i.e. is NOT
away from the plate stack).
</text></DescriptionText>
<DescriptionText><text>
This error is most likely caused either by someone putting the picker in the IN
position using the diagnostic commands or by a problem with the picker sensors.
The sensor status may be checked by using the PICKER command.
</text></DescriptionText>
<DescriptionText><text>
The sensor status should read TRUE if the sensor is activated. The sensors are
wired in series, so both of them need to be tripped for the status to read TRUE.
</text></DescriptionText>
<DescriptionText><text>
Check if the picker is in the OUT position (i.e. AWAY from the plate stack).
If it is, then refer to the service information for the E_ALE_PICKER_TIMEOUT
error.
</text></DescriptionText>
<DescriptionText><text>
It may be useful to set the 'verbose alcmd' parameter to 1 in order to obtain
further diagnostic information.
</text></DescriptionText>
</ServiceInformation>
<Cause>
Move Picker to 'out' position (AWAY from plate stack).
</Cause>
<Cause>
Refer to the service information for the E_ALE_PICKER_TIMEOUT error.
</Cause>
<Cause>
If the picker IS in the OUT position, then the picker out sensors may be
temporarily masked off by setting al pios to 0. Masking off these sensors will
get rid of the error message but will cause the machine to run significantly
slower than it used to.
</Cause>
<Cause>
WARNING:  Masking off sensors disables proper error checking!
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
<Link><LinkAddress>../commands/resume.xml</LinkAddress><LinkTitle>Command: resume</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_pios.xml</LinkAddress><LinkTitle>NVS: al pios</LinkTitle></Link>
<Link><LinkAddress>../nvs/verbose_cfg_alcmd.xml</LinkAddress><LinkTitle>NVS: verbose alcmd</LinkTitle></Link>
<Link><LinkAddress>../error_messages/15301.xml</LinkAddress><LinkTitle>E_ALE_PICKER_TIMEOUT</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:00 2008 PST
</Updated>
<Links>
</Links>
</Error>